Página 1 dos resultados de 202 itens digitais encontrados em 0.003 segundos

Thermal lens and heat generation of Nd : YAG lasers operating at 1.064 and 1.34 mu m

JACINTO, C.; CATUNDA, Tomaz; JAQUE, D.; BAUSA, L. E.; GARCIA-SOLE, J.
Fonte: OPTICAL SOC AMER Publicador: OPTICAL SOC AMER
Tipo: Artigo de Revista Científica
Português
Relevância na Pesquisa
36.14%
We report on a simple and accurate method for determination of thermo-optical and spectroscopic parameters (thermal diffusivity, temperature coefficient of the optical path length change, pump and fluorescence quantum efficiencies, thermal loading, thermal lens focal length, etc) of relevance in the thermal lensing of end-pumped neodymium lasers operating at 1.06- and 1.3-mu m channels. The comparison between thermal lensing observed in presence and absence of laser oscillation has been used to elucidate and evaluate the contribution of quantum efficiency and excited sate absorption processes to the thermal loading of Nd: YAG lasers. (c) 2008 Optical Society of America.

Microstructuration induced differences in the thermo-optical and luminescence properties of Nd:YAG fine grain ceramics and crystals

JACINTO, C.; BENAYAS, A.; CATUNDA, Tomaz; GARCIA-SOLE, J.; KAMINSKII, A. A.; JAQUE, D.
Fonte: AMER INST PHYSICS Publicador: AMER INST PHYSICS
Tipo: Artigo de Revista Científica
Português
Relevância na Pesquisa
46.27%
The temperature and compositional dependences of thermo- optical properties of neodymium doped yttrium aluminum garnet (YAG) crystals and fine grain ceramics have been systematically investigated by means of time- resolved thermal lens spectrometry. We have found that Nd:YAG ceramics show a reduced thermal diffusivity compared to Nd:YAG single crystals in the complete temperature range investigated (80-300 K). The analysis of the time- resolved luminescent properties of Nd(3+) has revealed that the reduction in the phonon mean free path taking place in Nd:YAG ceramics cannot be associated with an increment in the density of lattice defects, indicating that phonon scattering at grain boundaries is the origin of the observed reduction in the thermal diffusivity of Nd: YAG ceramics. Finally, our results showed the ability of the time- resolved thermal lens to determine and optimize the thermo- optical properties of Nd: YAG ceramic based lasers. (C) 2008 American Institute of Physics. [DOI: 10.1063/1.2975335]; Spanish Ministerio de Educacion y Ciencia[MAT-2007-64686]; Universidad Autonoma de Madrid; Comunidad Autonoma de Madrid[CCG07-UAM/MAT-1861]; CNPq; FAPESP; Coordenacao de Aperfeicoamento de Pessoal de Nivel Superior (CAPES); FAPEAL

Estudo clínico e histopatológico das cicatrizes de acne em pacientes fototipo II-V após irradiação com o laser Nd:Yag 1064 nm; Non-ablative 1064 nm Nd:Yag in the treatment of facial atrophic acne scars in patients with skin types II-V: histological and clinical analysis

Keller, Raquel
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 09/01/2007 Português
Relevância na Pesquisa
36.32%
Introdução: As cicatrizes de acne representam um problema difícil para médico e paciente. Os tratamentos das cicatrizes atróficas, embora numerosos, têm sido dificultados pelas inadequadas respostas clínicas e prolongados períodos de pós-opératório. O tratamento com os lasers não-ablativos tem mostrado significante efeito na remodelação do colágeno com mínimos efeitos colaterais pós-tratamento. Objetivos: Avaliar a eficácia e segurança do laser Nd:Yag 1064 nm no tratamento das cicatrizes de acne. Casuística e Método: Doze patientes (fototipo II-V) apresentando cicatrizes de acne, moderadas a severas, foram submetidos a cinco sessões mensais com o laser Nd:Yag 1064 nm (120J/cm2, pulso triplo, 7.0/7.0/7.0 milisegundos de duração e intervalo entre os pulsos de 75 milisegundos). Os pacientes foram avaliados por três dermatologistas, através de fotografias digitais que foram tiradas antes, no meio do tratamento e 6 meses após o último tratamento realizado. Avaliações histológicas de biópsias cutâneas foram obtidas antes do tratamento e 1 mês após a última sessão. A quantificação das fibras colágenas e elásticas, por área, antes e depois do tratamento foi feita pela morfometria com a análise de imagens analisadas por computador (método digital). A satisfação do patiente usando uma escala de graduação foi obtida no final do estudo. Resultados: Melhora suave a moderada foi observada depois dos cinco tratamentos na maioria dos pacientes estudados. A avaliação objetiva comparando as fotografias antes e depois do tratamento revelou melhora cosmética visível em 11 dos pacientes. A quantificação das fibras colágenas pela morfometria mostrou aumento delas após o tratamento...

Tratamento transureteroscópico do cálculo ureteral com HOLMIUM: YAG laser; Transureteroscopic treatment of ureteral stones with the Holmium:YAG laser

Sauer, Herbert
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 13/04/2004 Português
Relevância na Pesquisa
36.27%
Objetivo: O Holmium:YAG laser é o método de litotripsia intracorpórea para cálculos urinários mais recentemente introduzido em nosso meio. O objetivo deste estudo é analisar a eficácia e as complicações imediatas do tratamento de pacientes com cálculos ureterais com essa fonte de energia. Casuística e Métodos: Foram tratados 16 pacientes, nove homens e sete mulheres, portadores de cálculos ureterais sintomáticos, maiores ou iguais a 6 mm, ou com evolução superior a 30 dias. A média de idade foi 42 anos (6- 68 anos). Quatro cálculos estavam localizados no ureter superior, seis no ureter médio e seis no ureter inferior. A técnica empregada foi a de vaporização do cálculo com Holmium:YAG laser, através de ureteroscopia. Utilizou-se exclusivamente ureteroscópio semi-rígido de 7 Fr. Resultados: A taxa de sucesso obtida foi de 87,5%, sem diferença estatisticamente significativa em relação ao relatado na literatura. Todos os cálculos foram fragmentados. Os dois insucessos da série ocorreram com cálculos localizados em ureter superior, em que fragmentos foram deslocados para o rim. As complicações observadas foram três perfurações ureterais e dois casos de febre. Conclusão: O Holmium:YAG laser é eficaz no tratamento endoscópico do cálculo ureteral. Medidas destinadas a prevenir a migração retrógrada do cálculo ou de seus fragmentos devem ser tomadas...

Lasers de Nd:YAG nos regimes de nano e de picossegundos em esmalte e em dentina-análises morfológica e química; Nd:YAG picosecond and nanosecond lasers in enamel and dentin: morphological and chemical analysis

Lizarelli, Rosane de Fátima Zanirato
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 31/08/2000 Português
Relevância na Pesquisa
36.42%
Vários experimentos têm demonstrado que pulsos ultra curtos no domínio de subpicossegundos promovem uma combinação de efeitos termomecânicos que superam algumas das objeções ao uso de um laser como instrumento removedor. Usando os parâmetros apropriados de operação, lasers com pulsos ultra curtos podem se comportar melhor do que instrumentos convencionais, incluindo alguns dos lasers pulsados comercialmente já disponíveis na Odontologia. A exploração e otimização nos parâmetros dos lasers disponíveis podem promover a remoção de certas objeções ao amplo uso dos lasers. O uso de lasers de pulsos ultra-curtos para ablação de dentes previne o superaquecimento e é uma alternativa para a remoção mecânica de material; além de minimizar o volume desse material removido. Através de estudos morfológicos e químicos, são apresentadas as características de interação laser pulsado - tecido duro dental, com relação a sua largura de pulso - nano ou picossegundos. O objetivo principal é dar início a um novo sistema para ablação de esmalte e dentina humanos: o laser de Nd:YAG no regime de picossegundos. A eficiência da ablação com laser através de um regime de picossegundos minimiza a destruição do material adjacente devido a formação de plasma e ataque. Isso previne a geração excessiva de ondas de choque e promove uma considerável diminuição nos efeitos mecânicos. A diminuição das ondas de choque provavelmente também poderá reduzir a vibração e conseqüentemente a sensação de dor...

Avaliação in vitro da resistência ácida e da permeabilidade do esmalte dental decíduo irradiado com laser Nd:Yag associado ou não ao flúor; Analysis in vitro of acid resistance and permeability of primary tooth enamel after Nd:YAG laser irradiation, associated or not with fluoride

Azevedo, Danielle Torres
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 03/06/2011 Português
Relevância na Pesquisa
36.29%
A eficiência dos lasers associado ou não a fluoretos no aumento da resistência ácida e na redução da solubilidade do esmalte dentário tem sido confirmada em diversos estudos. Diversos comprimentos de onda têm sido utilizados com esta finalidade, apresentando bons resultados e representando uma abordagem preventiva simples e não invasiva. Apesar do emprego do laser Nd:YAG ter sua ação preventiva bem conhecida, são escassos os estudos em dentes decíduos, principalmente estudos que estabeleçam parâmetros seguros e eficientes, seja associado ao flúor ou isoladamente. Desta forma, o objetivo do presente estudo foi avaliar a resistência ácida e a permeabilidade do esmalte decíduo. Para tanto, foram selecionados 69 molares decíduos humanos, resultando em 132 corpos-de-prova. As variáveis de resposta quantitativa foram a microdureza longitudinal, profundidade da desmineralização e permeabilidade do esmalte, e as variáveis de resposta qualitativa foram morfologia da superfície, presença de íons flúor e análise dos componentes químicos do esmalte. Foram utilizados 60 fragmentos vestibular/lingual para a análise de resistência ácida e midrodureza (n=10), e após preparados e tratados, estes espécimes foram submetidos ao ciclo de desremineralização para formação de lesão de cárie artificial. Para análise da permeabilidade (48 fragmentos n=8)...

Desenvolvimento de metodologia para a produção de nanopartículas de Y3Al5O12 (YAG) de tamanhos médios diferenciados; Development of methodology for production of nanoparticles Y3Al5O12 (YAG) with different average sizes

Veroneze, Tatiana
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 22/09/2011 Português
Relevância na Pesquisa
36.3%
O desenvolvimento de materiais nanoestruturados tem se destacado devido a necessidade de miniaturização de dispositivos e a procura por novos efeitos físicos e químicos capazes de gerar novas tecnologias. Um importante composto com aplicações principalmente em óptica é o YAG (Y3Al5O12) presente no sistema cerâmico alumina-ítria ('AL IND.2'O IND.3'-'Y IND.2'O IND.3'). O YAG apresenta estrutura cristalina cúbica, expansão térmica isotrópica e não apresenta efeitos de birrefringência, o que possibilita a produção de cerâmica transparente para uso como material hospedeiro de íons terras-raras para o desenvolvimento de lasers de estado sólido. O ponto de partida em processamento cerâmico começa com o conhecimento das características físico-químicas do pó do composto. Em nosso trabalho, o objetivo foi o desenvolvimento de uma metodologia para a obtenção de nanopós de YAG de tamanhos médios diferenciados. Para isso foram realizados distintos processos químicos de síntese, e também, foram utilizados diferentes processos de separação, como a centrifugação e a sedimentação. Na produção das nanopartículas foram utilizados três métodos de síntese: Método de Pechini, Rota Glicerol e Método de Coprecipitação. No método de Pechini avaliou-se o efeito de diferentes valores de pH (1...

Uso do laser Nd:YAG na prevenção de cárie oclusal na dentição decídua e permanente: estudo in vivo e in vitro; Nd:YAG laser effect in caries prevention of primary and permanent dentition: in vivo and in vitro study

Raucci Neto, Walter
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 31/07/2013 Português
Relevância na Pesquisa
36.22%
O presente estudo teve por objetivo avaliar longitudinalmente in vivo e in vitro os efeitos do laser Nd:YAG na prevenção de cárie oclusal na dentição decídua e permanente. Foram selecionadas 52 crianças de alto risco à cárie (7,6 ± 1,4 anos). Os primeiros molares decíduos foram distribuídos entre os grupos controle negativo, controle positivo 1 (flúor fosfato acidulado - FFA) e controle positivo 2 (verniz fluoretado - VF). Os segundos molares decíduos e primeiros molares permanentes foram divididos entre os grupos experimentais: selante, irradiação laser (100mJ/5Hz-0,5W), irradiação laser + FFA e irradiação laser + VF. Os tratamentos foram aleatoriamente distribuídos entre os grupos experimentais e controles nos 4 quadrantes da cavidade bucal do paciente. Os pacientes foram submetidos a exames clínicos e radiográficos em 3, 6, 9, 12, 18 e 24 meses após o tratamento. As avaliações foram realizadas por três examinadores calibrados "cegos" aos tratamentos (K=0,92). Durante o período de avaliação os dentes decíduos esfoliados foram coletados e utilizados para os testes de microdureza, microscopia eletrônica de varredura (MEV), espectroscopia de energia dispersiva de raios-X (EDS), espectroscopia de infravermelho com transformada de Fourier (FTIR) e microscopia óptica (MO). 35 pacientes finalizaram o estudo e os dados das avaliações clínicas foram submetidos aos teste Q de Cochran (α=0...

Laser de Nd:YAG de alta potência, estabilidade e qualidade de feixe; High power Nd:YAG laser with high stability and beam quality

Pinto, Regiane de Souza
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 30/07/2014 Português
Relevância na Pesquisa
36.36%
O trabalho experimental aqui apresentado tem como foco o desenvolvimento de um laser de estado sólido cujo desempenho foi otimizado de tal forma que contemple alta potência, alta qualidade de feixe e estabilidade, levando-se em conta os efeitos térmicos sofridos pelo meio ativo em regime de alta potência de bombeamento. Foram testadas cavidades para operação contínua em multimodo com alta potência de saída e cavidades operando em modo único TEM00. Para cavidades operando no modo fundamental, os ressonadores testados serão divididos em grupos de acordo com o seu comportamento no diagrama de estabilidade. A otimização de tais ressonadores foi realizada apenas alterando-se o raio de curvatura dos espelhos de entrada e saída e suas respectivas distâncias ao plano principal do bastão de Nd:YAG. Como resultado foi alcançada a maior eficiência de extração reportada na literatura para um ou dois módulos de Nd:YAG intracavidade. Os resultados dão uma visão geral sobre possíveis projetos de ressonadores para operação dinamicamente estável, com alta potência de saída e qualidade de feixe. Os dados obtidos servem como base para o desenvolvimento de novos lasers de alta potência e eficiência baseados em módulos DPSSL (Diode-Pumped Solid-State Lasers- Lasers de Estado Sólido Bombeados por Diodo) de baixo custo.; The experimental work presented here focuses on the development of a solid-state laser whose performance has been optimized for high power output...

Microwave synthesis of YAG : Eu by sol-gel methodology

Pereira, Paula F. S.; Caiut, Jose M. A.; Ribeiro, Sidney J. L.; Messaddeq, Younes; Ciuffi, Katia J.; Rocha, Lucas A.; Molina, Eduardo F.; Nassar, Eduardo J.
Fonte: Elsevier B.V. Publicador: Elsevier B.V.
Tipo: Artigo de Revista Científica Formato: 378-382
Português
Relevância na Pesquisa
36.14%
Yttrium-aluminum oxides are interesting compounds and they have been extensively used as host for lasers and phosphors, due to their stable physical and chemical properties. The fabrication of yttrium-aluminum garnet (YAG) has been investigated thoroughly. Single-crystal YAG is expensive and to produce it a new way has been investigated. This process consists of modifying the methodology of reagents mixture and the process of heating them. The microwave irradiation is used to heat-treat the oxide mixture. The traditional synthesis of YAG powders occurs through the reaction of aluminum and yttrium powders at high temperatures. With this work we investigated the preparation of YAG by non-hydrolytic sol-gel route as an alternative methodology to obtain yttrium-aluminum matrix from inorganic precursors (yttrium and aluminum chloride). The preparation of the gel was carried out in an oven-dried glassware. The AlCl3, YCl3 and ethanol were reacted in reflux under argon atmosphere. Europium III chloride was added as a structural probe. The powder was dried and heat-treated in modified microwaves. The samples were pre-treated at 50 and 800 C during I h and then heated in microwaves for 30 s, 2 and 4 min. The formation process and structure of the powders were studied by means of X-ray diffraction (XRD)...

Enamel caries resistance accidentally irradiated by the Nd : YAG laser

de Andrade, L. E. H.; Lizarelli, R. F. Z.; Pelino, J. E. P.; Bagnato, V. S.; Oliveira, O. B. de
Fonte: Wiley-Blackwell Publicador: Wiley-Blackwell
Tipo: Artigo de Revista Científica Formato: 457-463
Português
Relevância na Pesquisa
36.11%
When the carious tissue is eliminated either by conventional methods (with burs) or with lasers, the risk of accidentally damage the surface of adjacent teeth may occur, which hypothetically could lead to a more susceptible surface for canes formation. This in vitro study aims to evaluate the caries resistance of the dental enamel surface irradiated by the Nd:YAG laser applied in conditions simulating accidental exposition. Thirteen third molars were used in this study. The experimental groups were: G1: sound control and control + carious; G2: contact Nd:YAG laser at 0.75, 1, 2, or 3 W; 10 Hz; 3 sec (27, 35, 71, and 106 J/cm(2)); G3: same parameters from G2 + caries artificial induction through the demineralization and demineralization (DES/RE) dynamic model. The caries resistance analysis was evaluated by the superficial morphological aspect through SEM images and also by Ca/P proportion through energy dispersive X-ray spectroscopy (EDX). The micrograph images showed that the Nd:YAG laser changed the normalmorphology of the enamel prisms resulting in a melted and re-solidified surface intensified with the power increase. Significant statistical differences were observed applying the Kruskal-Wallis statistical test (p <= 0.01) among the Nd:YAG laser irradiated groups and the control with caries regarding the Ca/P proportion. As an exception...

Avaliação da resistência de união em dentina submetida ao desafio erosivo: adesão ao substrato tratado com CPP-ACP e irradiado ou não com laser Nd:YAG

Kamozaki, Maria Beatriz Beber
Fonte: Universidade Estadual Paulista (UNESP) Publicador: Universidade Estadual Paulista (UNESP)
Tipo: Dissertação de Mestrado Formato: 81 f. : il.
Português
Relevância na Pesquisa
36.11%
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES); Pós-graduação em Odontologia Restauradora - ICT; O estudo avaliou a influência do CCP-ACP (casein phosphopeptide – amorphous calcium phosphate) e CPP-ACP associado ao NaF, na resistência de união à dentina submetida ao desafio erosivo por bebida ácida, com ou sem irradiação por laser Nd:YAG. Foram utilizados 60 molares humanos, os quais tiveram a porção coronária seccionada mesio-distalmente, obtendo dois espécimes. Após a exposição da dentina, os espécimes foram embutidos em resina acrílica quimicamente ativada. Quatro grupos (n=30) foram obtidos: GC (grupo controle); DE (desafio erosivo); DE.M (desafio erosivo + MI Paste); DE.MP (desafio erosivo + MI Paste Plus). O desafio erosivo foi realizado pela imersão única das amostras em Sprite Zero, durante 30 min. Os grupos DE.M e DE.MP foram submetidos ao tratamento remineralizador com a aplicação de uma camada de aproximadamente 0,5mm por 3 min. Os grupos foram divididos em dois subgrupos: SL (sem laser Nd:YAG) e CL (sistema adesivo + laser Nd:YAG + fotopolimerização). A densidade de energia utilizada foi 174J/cm2, 140 mJ/pulsos, 10 Hz, 1,4W. Todos os espécimes foram restaurados com o sistema adesivo Clearfil SE Bond (Kuraray) e a resina composta Z350XT (3M-ESPE). Após 24h de armazenagem em água deionizada...

Influência da aplicação do Nd:YAG laser sobre sistema adesivo na variação da temperatura pulpar

Silva, Tânia Mara da
Fonte: Universidade Estadual Paulista (UNESP) Publicador: Universidade Estadual Paulista (UNESP)
Tipo: Dissertação de Mestrado Formato: 119 f. : il.
Português
Relevância na Pesquisa
36.12%
Pós-graduação em Odontologia Restauradora - ICT; O objetivo deste estudo foi avaliar os efeitos da irradiação de Nd:YAG laser e da pressão pulpar simulada na variação de temperatura intrapulpar. Cem molares humanos hígidos foram seccionados 1 mm abaixo da junção amelocementária para separação da coroa da porção radicular e seccionados paralelos à superfície oclusal para exposição de 2 mm de espessura de dentina. As amostras foram divididas aleatoriamente em 2 grupos (n=50) de acordo com a presença e ausência de pressão pulpar simulada. Cada grupo foi dividido em 5 subgrupos (n=10) conforme a variação nos parâmetros de energia do Nd:YAG laser: 60, 80, 100, 120 e 140 mJ. As amostras foram tratadas com: ácido fosfórico 37% (Scotchbond Universal), sistema adesivo Scotchbond Universal (3M ESPE), irradiação com Nd:YAG laser por 60 s e fotopolimerização por 10 s. Avaliou-se a temperatura intrapulpar por meio de um termômetro digital posicionado no corno pulpar mais alto. A pressão pulpar simulada foi de 15 cm de H2O. Para o grupo sem pressão pulpar simulada, a câmara pulpar foi preenchida com pasta térmica. A análise estatística consistiu nos testes ANOVA 2-fatores (parâmetros de energia do laser e pressão pulpar) e Tukey com nível de significância de 5% (p<0...

Estudo longitudinal da resistência adesiva aos substratos dentários de sistemas adesivos associados ou não ao Nd:YAG Laser

Barcellos, Daphne Camara
Fonte: Universidade Estadual Paulista (UNESP) Publicador: Universidade Estadual Paulista (UNESP)
Tipo: Tese de Doutorado Formato: 183 f. : il.
Português
Relevância na Pesquisa
36.13%
Pós-graduação em Odontologia Restauradora - ICT; O objetivo deste estudo foi avaliar a resistência de união dos sistemas adesivos Clearfil SE Bond (CL) e Single Bond (SB) ao esmalte e dentina, em função da associação ou não do Nd:YAG Laser e do tempo de armazenagem (24 h e 12 meses). Foram utilizados 240 dentes bovinos com superfícies de esmalte ou dentina planificadas, que foram divididos em 4 grupos (n = 15) para cada substrato, de acordo com o sistema adesivo e a técnica: G1 (Controle) - CL + fotopolimerização; G2 (Controle) - SB + fotopolimerização; G3 (Experimental/Laser) - CL + Nd:YAG Laser + fotopolimerização; G4 (Experimental/Laser) - SB + Nd:YAG Laser + fotopolimerização. Para o esmalte, foi utilizada a densidade de energia = 174,16 J/cm2 e, para a dentina, a densidade de energia = 149,28 J/cm2 do Nd:YAG Laser. Foram confeccionadas restaurações de resina composta Z-350. Após armazenagem de 24 h ou 12 meses em água destilada à 37º C, foram realizadas as secções nos dentes para obtenção de amostras com área adesiva de aproximadamente 1 mm2, seguido de teste de microtração. Para cada substrato, foi realizado o teste estatístico ANOVA três fatores (Sistema adesivo X Técnica X Tempo de armazenagem)...

Efeito da aplicação de sistemas adesivos autocondicionantes associados ao laser Nd:YAG na prevenção do desgaste erosivo/abrasivo do esmalte dental

Crastechini, Érica
Fonte: Universidade Estadual Paulista (UNESP) Publicador: Universidade Estadual Paulista (UNESP)
Tipo: Dissertação de Mestrado Formato: 75 f. : il.
Português
Relevância na Pesquisa
36.15%
Pós-graduação em Odontologia Restauradora - ICT; The aim of this study was to evaluate the effectiveness of the Nd: YAG laser, alone or associated with different auto constraints adhesive systems, in the prevention of erosive and abrasive wear of the dental enamel. A hundred and sixty samples of bovine enamel were prepared, polished and subjected to an initial erosion in 0.3 % citric acid solution for 5 min. The initial profiles of the enamel surface were measured using a profilometer, whose unit is measured in micrometers (μm). The samples were randomly divided into eight groups (n = 20): SB - Single Bond Universal (3M/Espe) adhesive application and light curing; SB+L - Single Bond Universal adhesive application, Nd:YAG laser irradiation (80 mJ, 10 Hz) and light curing; FB - Futura Bond U (Voco) adhesive application and light curing; Group FB+L - Futura Bond U adhesive application, Nd:YAG laser irradiation and light curing; GEN - G-aenial Bond (GC) adhesive application and light curing; GEN+L - G-aenial Bond adhesive, Nd:YAG laser irradiation and light curing; L - Only Nd:YAG laser irradiation; C - No treatment (control group). The erosive challenge, using citric acid 0.3 % (pH 2.6) for 2 min, and abrasive challenge, using a tooth brushing machine (40 cycles...

Efeito longitudinal de tratamentos de superfície modificados por Nd:YAG laser na permeabilidade dentinária

Esteves, Stella Renata Machado Silva
Fonte: Universidade Estadual Paulista (UNESP) Publicador: Universidade Estadual Paulista (UNESP)
Tipo: Dissertação de Mestrado Formato: 97 f. : il
Português
Relevância na Pesquisa
36.13%
Pós-graduação em Odontologia Restauradora - ICT; Dentin hypersensitivity affects a large population and generates a lot of discomfort. Most treatments are based on the use of agents to reduce permeability with their effect related to individual factors and with low longevity. The aim of this study was to evaluate in vitro the efficacy and longevity of treatments for reducing dentin permeability, such as fluoride, adhesives and collagen deproteinization, associated or not with Nd : YAG laser by measuring the dentinal fluid flow in a permeability machine ( Odeme , Brazil). Seventy bovine dentin specimens of 6mm diameter and 1 mm thickness were divided into 7 groups according to treatment: Group C: control without treatment; Group F: fluoride varnish; Group FL: fluoride varnish + Nd:YAG laser, Group A: Scotchbond Universal, Group AL: adhesive + Nd:YAG laser, Group D: 10 % NaOCl + adhesive; group DL: 10 % NaOCl, adhesive + Nd:YAG laser. The specimens had dentin permeability measured in 4 phases: in the presence of the occlusal smear layer (Minimum Permeability), after EDTA application for 1 min (Maximum Permeability), after the treatments and after erosion / abrasive challenge; in order to analyze the effectiveness and durability of each treatment. RM ANOVA (2 factors) and Tukey (α = 0...

Deployable stable lasers for gravitational wave interferometers.

Hosken, David John
Fonte: Universidade de Adelaide Publicador: Universidade de Adelaide
Tipo: Tese de Doutorado
Publicado em //2009 Português
Relevância na Pesquisa
36.17%
The most promising technique for the direct, ground-based detection of gravitational waves is the use of advanced interferometric gravitational wave detectors. These detectors use long-baseline Michelson interferometers, where the critical enabling component is the laser. The laser required for these interferometers must provide a low noise, single frequency, diffraction limited, high power TEM₀₀ beam. Very importantly, the laser beam must be available continuously and without the need for operator intervention. In this thesis I describe the development and characterisation of injection-locked 10 W Nd:YAG lasers, designed specifically for use at the Australian Consortium for Interferometric Gravitational Astronomy (ACIGA) High Power Test Facility (HPTF) in Western Australia, and on the Japanese TAMA 300 gravitational wave interferometer (GWI). The starting point was a 5 W laboratory laser that had demonstrated the proof-of-principle; however this laser had insufficient power, inadequate reliability, and was not suitable for deployment to a remote site. I describe the development of this laser technology and design to realise reliable, longterm operation and field deployability, while satisfying the requirements for a GWI, with the final laser system bearing little resemblance to the proof-of-principle system. Injection-locked lasers were successfully installed at the ACIGA HPTF and at TAMA 300 in June 2004 and September 2005 respectively. The 10 W laser uses a Nd:YAG Coplanar Pumped Folded Slab (CPFS) gain medium. The slab is side-pumped using a temperature controlled...

1064 nm injection mode-locked Nd:YAG laser optimized for guide star applications.

Rutten, Thomas P.
Fonte: Universidade de Adelaide Publicador: Universidade de Adelaide
Tipo: Tese de Doutorado
Publicado em //2010 Português
Relevância na Pesquisa
36.27%
In recent years, the emergence of powerful, sodium-resonant laser sources has led to a dramatic improvement in resolution at many of the world’s large aperture observatories. The lasers are used to create artificial beacons (or guide stars) by fluorescing atmospheric sodium. Light from the beacon, returning from altitude, probes the intervening turbulence and the phase distortions detected are subsequently corrected using adaptive optics. Near-diffraction limited imaging has now been achieved on observatories with diameters up to 8 m using this technique. Future 30-100 m diameter telescopes will require new laser sources having higher average powers and innovative pulse formats to implement new forms of atmospheric tomography and correction. In this thesis I present the design and development of a new laser system for this purpose. The laser design that I describe uses sum frequency generation (SFG) of 1064 nm and 1319 nm Nd:YAG lasers to produce the sodium wavelength, and introduces the novel application of injection mode-locking as a robust method to control the lasers wavelength and bandwidth. The high peak power and low timing jitter of the mode-locked (micro) pulses allows for efficient SFG of the 1064 and 1319 nm beams. Each slave laser is Qswitched and the duration of the Q-switched (macro) pulses are optimised to reduce star elongation and bleaching of the sodium. The experimental work presented in this thesis is focused on the realization of a 1064 nm injection mode-locked slave laser...

Effect of a Single Application of TiF(4) and NaF Varnishes and Solutions Combined with Nd:YAG Laser Irradiation on Enamel Erosion in Vitro

MAGALHAES, Ana Carolina; ROMANELLI, Andrea Cardinalli; RIOS, Daniela; COMAR, Livia Picchi; NAVARRO, Ricardo Scarparo; GRIZZO, Larissa Tercilia; ARANHA, Ana Cecilia Correa; BUZALAF, Marilia Afonso Rabelo
Fonte: MARY ANN LIEBERT INC Publicador: MARY ANN LIEBERT INC
Tipo: Artigo de Revista Científica
Português
Relevância na Pesquisa
36.16%
Objective: This in vitro study aimed to analyze the influence of neodymium-doped yttrium aluminum garnet (Nd:YAG) laser irradiation on the efficacy of titanium tetrafluoride (TiF(4)) and sodium fluoride (NaF) varnishes and solutions to protect enamel against erosion. Background data: The effect of Nd:YAG laser irradiation on NaF and AmF was analyzed; however, there is no available data on the interaction between Nd:YAG laser irradiation and TiF(4). Methods: Bovine enamel specimens were pre-treated with NaF varnish, TiF(4) varnish, NaF solution, TiF(4) solution, placebo varnish, Nd:YAG (84.9 J/cm(2)), Nd:YAG prior to or through NaF varnish, Nd:YAG prior to or through TiF(4) varnish, Nd:YAG prior to or through NaF solution, Nd:YAG prior to or through TiF(4) solution, and Nd:YAG prior to or through placebo varnish. Controls remained untreated. Ten specimens in each group were then subjected to an erosive demineralization (Sprite Zero, 4x90 s/day) and remineralization (artificial saliva, between the erosive cycles) cycling for 5 days. Enamel loss was measured profilometrically (mu m). Additionally, treated but non-eroded specimens were additionally analyzed by scanning electron microscope (SEM) (each group n-2). The data were statistically analyzed by ANOVA and Tukey's post-hoc test (p < 0.05). Results: Only TiF(4) varnish (1.8 +/- 0.6 mu m)...

Infiltração apical em obturações de canais realizadas após aplicação do laser Nd: YAG ou solução de EDTA nas paredes do canal radicular; Apical leakage in root canal fillings performed with two types of cement following application of Nd: YAG laser or EDTA solution in the root canal walls

Bassili, Leandro de Oliveira; Moraes, Ivaldo Gomes de; Zanetti, Raquel Virginia
Fonte: Universidade de São Paulo. Faculdade de Odontologia de Bauru Publicador: Universidade de São Paulo. Faculdade de Odontologia de Bauru
Tipo: info:eu-repo/semantics/article; info:eu-repo/semantics/publishedVersion; ; Formato: application/pdf
Publicado em 01/06/2003 Português
Relevância na Pesquisa
36.27%
Avaliou-se a infiltração marginal apical em obturações endodônticas utilizando dois tipos de cimentos após a aplicação do laser Nd:YAG ou solução de EDTA nas paredes do canal radicular. Utilizou-se sessenta e dois dentes pré-molares inferiores humanos que tiveram seus canais radiculares instrumentados por técnica mecanizada. Em seguida, as superfícies externas radiculares foram impermeabilizadas, exceto o forame apical. As raízes foram, então, divididas em 4 grupos de 15, de acordo com o tipo de tratamento realizado nas paredes dos canais radiculares e o tipo de cimento utilizado para a obturação. Grupo I - aplicação do laser Nd:YAG e obturação com cimento AH Plus; Grupo II - aplicação do laser Nd:YAG e obturação com cimento Endofill; Grupo III - aplicação de EDTA por 5 minutos e obturação com cimento AH Plus; Grupo IV - aplicação de EDTA por 5 minutos e obturação com cimento Endofill. Dois dentes serviram como controles positivo e negativo. Em seguida, as raízes foram imersas em solução de azul-de-metileno a 2%, durante 48 horas. Após remoção da impermeabilização foi realizado o desgaste das raízes para leitura da magnitude das infiltrações, por meio de um microscópio óptico pela técnica da planimetria. Os resultados indicaram que o cimento AH Plus foi o que permitiu menor infiltração apical...