Página 1 dos resultados de 12245 itens digitais encontrados em 0.009 segundos

A new DTL-electrode holder for recording of electroretinograms in animals

SCHATZ, A.; WILLMANN, G.; ENDERLE, H.; SLIESORAITYTE, I.; MESSIAS, A.; BARTZ-SCHMIDT, K. U.; ZRENNER, E.; GEKELER, F.
Fonte: ELSEVIER SCIENCE BV Publicador: ELSEVIER SCIENCE BV
Tipo: Artigo de Revista Científica
Português
Relevância na Pesquisa
36.8%
Purpose: Contact lens electrodes (CLEs) are frequently used to register electroretinograms (ERGs) in small animals such as mice or rats. CLEs are expensive to buy or difficult to be produced individually. In addition, CLE`s have been noticed to elicit inconstant results and they carry potential to injure the cornea. Therefore, a new electrode holder was constructed based on the clinically used DTL-electrode and compared to CLEs. Material and methods: ERGs were recorded with both electrode types in nine healthy Brown-Norway rats under scotopic conditions. For low intensity responses a Naka-Rushton function was fitted and the parameters V(max), k and n were analyzed. The a-wave, b-wave and oscillatory potentials were analyzed for brighter flash intensities (1-60 scot cd s/m(2)). Repeatability was assessed for both electrode types in consecutive measurements. Results: The new electrode holder was faster in setting up than the CLE and showed lower standard deviations. No corneal alterations were observed. Slightly higher amplitudes were recorded in most of the measurements with the new electrode holder (except amplitudes induced by 60 cd s/m(2)). A Bland-Altman test showed good agreement between the DTL holder and the CLE (mean difference 35.2 mu V (Holder-CLE)). Pearson`s correlation coefficient for test-retest-reliability was r = 0.783. Conclusions: The DTL holder was superior in handling and caused far less corneal problems than the CLE and produced comparable or better electrophysiological results. The minimal production costs and the possibility of adapting the DTL holder to bigger eyes...

Estudo eletroquímico e estrutural do eletrodo de hidróxido de níquel modificado com cério para estabilização da fase α-Ni(OH0)2; Electrochemical and structural study of the electrode of hydroxide of nickel modified with cerium for stabilization of the phase 945;-Ni(OH)2

Bragagnolo, Gislaine Maria
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Dissertação de Mestrado Formato: application/pdf
Publicado em 25/11/2005 Português
Relevância na Pesquisa
36.77%
O Ni(OH)2 é amplamente utilizado como principal componente ativo do eletrodo positivo na maior parte das baterias secundárias como: Ni/Cd, Ni/Zn, Ni/Fe, Ni/H2 e, recentemente na pilhas de Ni/MH. Estes acumuladores possuem variadas aplicações como: satélites geoestacionários, alimetação de recarga de computadores, aparelhos portáteis. Apesar do eletrodo de Ni(OH)2 possuir boa durabilidade, após vários ciclos de oxidação/redução ocorre a transformação do par redox α-Ni(OH)2/β-NiOOH para β-Ni(OH)2/γ-NiOOH o qual ocasiona uma diminuição na capacidade de carga. Por essa razão, é necessário o estudo do efeito de aditivos para estabilização da capacidade de carga no eletrodo. Neste trabalho, hidróxido de cério foi utilizado como aditivo para estabilizar o α-Ni(OH)2. Os resultados obtidos mostram que os íons cério são incorporados no eletrodo estabilizando a fase α-Ni(OH)2 e com isso aumentando a capacidade de carga do mesmo. Nas análises de espectroscopia no IV e Raman foi possível verificar modificações estruturais causadas pela presença de íons Ce3+ na estrutura, principalmente, a partir de 21,33% em mol do aditivo. Nos estudos de ciclagens sucessivas a fase α-Ni(OH)2 foi estabilizada na presença de 21...

Influência dos íons cloreto na cinética de redução eletroquímica dos íons de Bi+3 e CU2+ no eletrodo de mercúrio; Influence of chloride ions on the electrochemical reduction of Bi3+ and Cu2+ ions on mercury electrode

Agostinho, Silvia Maria Leite
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 03/11/1975 Português
Relevância na Pesquisa
36.82%
A influência de pequenas concentrações de íons cloreto na cinética de redução eletroquímica dos íons Bi3+ e Cu2+ foi estudada através de medidas independentes de adsorção específica e de cinética eletroquímica. A adsorção específica foi determinada por meio das curvas eletrocapilares obtidas com o método do tempo de gota, para soluções aquosas de misturas de ácido clorídrico xM e de ácido perclórico (1 - x)M. Obeservou-se que, em concentrações de cloreto muito baixas, iguais ou inferiores a 10-2 M, a adsorção específica desses íons segue a isoterma de adsorção de Henry. A cinética da redução eletroquímica dos íons de Bi3+ e Cu2+, na presença de pequenas concentrações de íons cloreto, em meio de ácido perclórico 1 M, foi estudada por polarografia com o eletrodo de mercúrio. Os valores das constantes de velocidade foram calculados, a partir da relação existente entre a corrente, medida em cada potencial, e a corrente de difusão, usando as equações relativas a processos de eletrodos irreversíveis. Estes valores mostraram que, para as concentrações mais baixas de cloreto estudadas, esses íons aceleram as reações Bi3+ + 3e → Bi(Hg) e Cu2+ + 2e → Cu(Hg). O mecanismo de redução...

Estudos de adsorção e equilíbrio nos sistemas Cd(II) / SCN-/ C6H12N4 e Cd(II)/I-/SCN-. aperfeiçoamento de métodos e eletrodo; Adsorption and equilibrium studies of the systems Cd(II)/SCN-/C6N12H14 and Cd(II)/I-/SCN-. Improvement of methods and of the electrode

Angnes, Lucio
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 07/12/1987 Português
Relevância na Pesquisa
36.8%
Na presente tese investigou-se a adsorção induzida de um cátion metálico (cádmio(II)) na presença simultânea de dois ligantes (um pseudo-haleto e uma amina ou haleto) na interface eletrodo de mercúrio/solução aquosa, com vistas a uma melhor compreensão desse processo. Os estudos de adsorção foram precedidos por estudos de equilíbrio dos compostos de coordenação formados em solução aquosa. Medidas experimentais foram feitas por potenciometria com eletrodo de amálgama, em força iônica 1,00 M, ajustada com NaCl04. Análise dos dados por programas computacionais adequados levou à quantificação das constantes de estabilidade de 7 espécies binárias e 9 espécies mistas para o sistema Cd(II)/ SCN-/C6H12N4 e de 8 espécies binárias e 6 mistas para o sistema Cd(II)/I-/SCN-, sendo todas estas espécies mononucleares. Para possibilitar um maior grau de automação das medidas cronocoulométricas de adsorção, o eletrodo de gota pendente de mercúrio, anteriormente desenvolvido no IQ-USP, teve seu sistema mecânico aperfeiçoado e passou a ser controlado por computador. O "software" se incumbe de calcular e comandar o tempo de abertura da micro-válvula do eletrodo para gerar gotas com a área solicitada. Aproveitando a possibilidade de realizar aquisição (de dados de carga durante e após a formação das gotas de mercúrio...

Aplicação do eletrodo de diamante dopado com boro modificado pelo método Sol-Gel para determinação e degradação de carbaril; Application of boron-doped diamond electrode modified by Sol-Gel method for determination and degradation of carbaryl

Teixeira, Milena Elias
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 21/09/2012 Português
Relevância na Pesquisa
36.8%
São apresentados os resultados do estudo das propriedades eletroquímicas do eletrodo de diamante dopado com boro (DDB) e do eletrodo de DDB modificado diretamente pelo método Sol-Gel com PbOx, para a determinação de carbaril. Mostrou-se que uma polarização anódica (3,0 V vs Ag/AgCl, 30 min) seguida de uma catódica (-3,0 V vs Ag/AgCl, 30 min), em meio ácido, são apropriadas para otimizar o desempenho catalítico da superfície. As imagens de AFM mostraram alterações topológicas significativas no eletrodo de PbOx/DDB, assim como as imagens digitais apresentaram uma provável mistura de óxidos de chumbo depositados na superfície do DDB. Caracterizações físicas do modificador PbOx foram realizadas com as técnicas de Microscopia Eletrônica de Varredura (MEV), Difratometria de raios-X (DRX) e Energia Dispersiva de raios-X (EDS). A MEV verificou os aspectos morfológicos da amostra e revelou que as partículas do modificador tinham formatos e tamanhos diferentes, distribuídas irregularmente. O difratograma de DRX confirmou a existência de uma mistura de óxidos de chumbo, produzida pelo método Sol-Gel e a análise por EDS mostrou a presença dos elementos chumbo e oxigênio, com proporção atômica de 43:57 (Pb:O). Para a determinação eletroanalítica do pesticida carbaril...

Desenvolvimento de um eletrodo amperometrico para determinação de glutationa em eritrocitos; Development of an amperometric electrode for determination of glutathione in erythrocytes

Percy Calvo Marzal
Fonte: Biblioteca Digital da Unicamp Publicador: Biblioteca Digital da Unicamp
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 08/08/2005 Português
Relevância na Pesquisa
36.82%
O presente trabalho refere-se ao desenvolvimento de um novo método para determinação de glutationa em eritrócitos, utilizando o método amperométrico. Para isto um eletrodo a base de pasta de carbono modificado com o complexo tetratiofulvaleno-tetracianoquinodimetano (TTF-TCNQ) foi desenvolvido, com o intuito de possibilitar a transferência de elétrons entre a glutationa e o eletrodo a baixos potenciais. O eletrodo modificado apresentou boas características em termos de seletividade, sensibilidade e tempo de resposta, facilitando sua operacionalidade para a detecção de glutationa. Com a modificação do eletrodo foi possível obter uma resposta bastante sensível para glutationa num potencial de 200 mV vs ECS. As melhores condições foram verificadas com 20% (m/m) de TTF-TCNQ incorporado na pasta de carbono e 0,5% de Nafion (m/v). As medidas foram realizadas em tampão fosfato pH 8,0 contendo KCl 0,1 mol L e EDTA 0,5 mmol L. Nessas condições, o eletrodo modificado apresentou um intervalo de resposta linear entre 5 a 340 mmol L de glutationa ajustado pela equação Dj = 0,7(±0,1) + 90,1(±0,4)[GSH] com um coeficiente de correlação de 0.9998 para n = 20, onde a densidade de corrente Dj é dada em mA cm e a concentração da GSH em mmol L. O tempo de resposta do eletrodo foi de 0...

Electroretinography in dogs using a fiber electrode prototype

Pereira,A.L.; Montiani-Ferreira,F.; Santos,V.R.; Salomao,S.R.; Souza,C.; Berezovsky,A.
Fonte: Associação Brasileira de Divulgação Científica Publicador: Associação Brasileira de Divulgação Científica
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/03/2013 Português
Relevância na Pesquisa
36.8%
We compared two electroretinography (ERG) electrodes in dogs using ERG standards of the International Society for Clinical Electrophysiology of Vision (ISCEV). Ten healthy Yorkshire terrier dogs (mean age, 2.80 ± 1.42 years; 6 females) weighing 5.20 ± 1.56 kg were evaluated using an ERG system for veterinary use. Dark- and light-adapted ERG responses were recorded using an ERG-Jet electrode and a fiber electrode prototype. The examinations were performed during 2 visits, 3 weeks apart. Both electrodes (ERG-Jet or fiber prototype) were used on each animal and the first eye to be recorded (OD × OS) was selected randomly. Three weeks later the examination was repeated on the same animal switching the type of electrode to be used that day and the first eye to be examined. The magnitude and waveform quality obtained with the two electrode types were similar for all ERG responses. ERG amplitudes and implicit times obtained from dogs using the fiber electrode prototype were comparable to those obtained with the ERG-Jet electrode for rod, maximal rod-cone summed, cone, and 30-Hz flicker responses. The fiber electrode prototype is a low-cost device...

Iodide-selective membrane electrode based on salophen complex of cobalt (III)

Zare,Hamid R.; Memarzadeh,Farkhondeh; Gorji,Alireza; Ardakani,Mohammad Mazloum
Fonte: Sociedade Brasileira de Química Publicador: Sociedade Brasileira de Química
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/06/2005 Português
Relevância na Pesquisa
36.77%
A highly selective PVC membrane electrode based on a cobalt-salophen complex was prepared. The sensor displays an anti-Hofmeister selectivity sequence with a preference for iodide ion over many common anions. The electrode has a linear dynamic range between 5.0×10-7 to 1.0×10-1 mol L-1, with a Nernstian slope of -58.9 mV decade-1 and a detection limit of 3.0×10-7 mol L-1. The working pH range of the sensor is 3.1-9.8. It exhibits of a fast as 15 s and has a lifetime of about 2 months. The selectivity coefficients for the proposed electrode were improved for some interferences, when compared with those of available iodide membrane electrode. The proposed electrode was successfully applied for the direct determination of iodide in edible salt and as an indicator electrode in potentiometric titration of I- against Ag+.

Electrocatalytic oxidation of thiosulfate at glassy carbon electrode chemically modified with cobalt pentacyanonitrosylferrate

Sabzi,Reza E.
Fonte: Sociedade Brasileira de Química Publicador: Sociedade Brasileira de Química
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/12/2005 Português
Relevância na Pesquisa
36.77%
An electroactive thin film of Cobalt pentacyanonitrosylferrate (CoPCNF) was electrodeposited on a glassy carbon electrode by cyclic voltammetry. The modified electrode exhibits good electrocatalytic activity toward oxidation of thiosulfate. The electrocatalytic oxidation of thiosulfate at glassy carbon electrode modified with CoPCNF as a working electrode has been studied by using cyclic voltammetry, rotating disk electrode (RDE) voltammetry and chronoamperometry in a solution of 0.25 mol L-1 KNO3 as a supporting electrolyte. A Tafel plot, derived from voltammograms indicated a one-electron charge transfer process, at rate determining step in the catalytic oxidation of thiosulfate. The kinetics of catalytic reaction was investigated and the average value of the rate constant (k), for the catalytic reaction and the diffusion coefficient (D) were evaluated by different approaches for thiosulfate and found to be (5.61 ± 0.14) ´10² (mol L-1)-1s-1 and (6.59 ± 0.70) ´10-6 cm²s-1 respectively.

Potentiometric coated wire electrode for salicylate based on zinc(II) acetylacetonate

Ardakani,M. Mazloum; Pourhakkak,P.; Salavati-Niasari,M.
Fonte: Sociedade Brasileira de Química Publicador: Sociedade Brasileira de Química
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/01/2007 Português
Relevância na Pesquisa
36.8%
A coated-wire ion selective electrode based on zinc(II) acetylacetonate as ionophore exhibited linear response with Nernstian slope of -59.6 ± 1.0 mV/decade over a wide concentration range (1.0´10-5-1.0´10-1 mol L-1). This electrode has 5.0´10-6 mol L-1 detection limit. The proposed electrodes has a response time between 5-10 s to achieve a 95% steady potential for salicylate concentrations. The electrode was suitable for use in aqueous solutions in a wide pH range of 2.7 to 7.8. The electrode life time was tested over a period of two months to investigate its stability. No significant change in the performance of the electrode was observed during this period, but after two months, a gradual decrease ocurred in the slope. The proposed electrode showed high selectivity for salicylate over a number of common inorganic and organic anions. The electrode was successfully applied to the determination of salicylate in pharmaceutical samples.

Evaluation study of an ion selective field effect transistor electrode for measuring quality parameters of fuel ethanol

Gonzaga,Fabiano B.; Sobral,Sidney P.; Ribeiro,Carla M.; Gonçalves,Mary A.
Fonte: Sociedade Brasileira de Química Publicador: Sociedade Brasileira de Química
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/01/2013 Português
Relevância na Pesquisa
36.82%
An ion selective field effect transistor (ISFET) electrode was evaluated for measuring pH and acid number (AN) of fuel ethanol and compared to two glass electrodes with different reference filling solutions: KCl aqueous solution (glass-KCl electrode) and LiCl ethanolic solution (glass-LiCl electrode). pH was determined at different measurement times and AN was determined using automatic potentiometric titration. For pH, the glass-KCl electrode showed the best precision and stability, with an average repeatability about four times better when compared to the ISFET electrode for the measurement time of 30 s (as indicated in the ASTM D6423 standard). For AN, the glass-KCl and glass-LiCl electrodes showed similar repeatabilities, which were about three times better than that of the ISFET electrode. In addition, the results from a recovery study demonstrated better accuracy of the glass-LiCl electrode, with a recovery value of 100.1%.

Preparation of a composite particle electrode by electroless plating and its electrocatalytic performance in the decolorization of methyl orange dye solution

Cao,Guiping; Xu,Feng; Xia,Shengan
Fonte: Sociedade Brasileira de Química Publicador: Sociedade Brasileira de Química
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/12/2013 Português
Relevância na Pesquisa
36.89%
A nickel-loaded activated carbon (Ni/AC) composite particle electrode was prepared by electroless deposition with palladium-free pretreatment to improve the electrocatalytic performance of a composite particle electrode in a three-dimensional electrode cell. The preparation conditions of the Ni/AC particle electrode were optimized using the decolorization ratio of methyl orange dye solution as an index. The composite particle electrodes were characterized by scanning electron microscopy, X-ray diffraction, and energy dispersive spectrometry analyses. The electrocatalytic performances of the Ni/AC particle electrode were examined by a series of parameters, including particle electrode dose, sodium sulfate concentration, cell voltage, and electrolysis time. The results were compared with those of conventional activated carbon (AC) particle electrode. These results indicated the feasibility of preparing a Ni/AC composite particle electrode by electroless plating with non-palladium pretreatment. The optimal conditions for preparing the Ni/AC electrode were 40 g L-1 NiSO4·6H2O, 27 g L-1 NaH2PO2·H2O, 50 °C plating temperature, and 20 min plating time. The electrocatalytic performance of Ni/AC electrode was superior to that of AC electrode under the same electrolysis conditions. The rate constant of the Ni/AC electrode electrochemical oxidation of methyl orange was 1.5 times larger than that of AC electrode.

Surface Electromyography of the Pelvic Floor Musculature: Reliability and Validity of a Novel Electrode Design

Keshwani, Nadia
Fonte: Quens University Publicador: Quens University
Tipo: Tese de Doutorado
Português
Relevância na Pesquisa
36.84%
Purpose: Intravaginal probes used for recording electromyography (EMG) from the pelvic floor muscles (PFMs) likely record activity from nearby muscles (crosstalk), and move during functional tasks, causing motion artifact data contamination, threatening the validity of results obtained. This study investigated the test-retest reliability and validity of surface EMG recordings from the PFMs using a novel, theoretically superior electrode in comparison to a commercially available intravaginal probe, the FemiscanTM. Methods: Healthy subjects (n=20) performed tasks with each vaginal electrode in situ: i) PFM maximal voluntary contractions (MVC), ii) coughs, iii) unilateral hip adductor/external rotator contractions at 25%MVC, 50%MVC, and MVC while keeping the PFMs relaxed or maximally contracted, and iv) transversus abdominis contractions (TrA; recorded using fine-wires) at 25%MVC, 50%MVC, MVC. Analyses: i) Intraclass correlation coefficients (ICC), ii) t-tests of proportions (α=0.05), iii) repeated measures ANOVAs and Tukey’s post-hoc testing (α=0.05) and iv) cross-correlation functions between peaks of transversus abdominis and PFM activity were used to determine the between-trial and between-day reliability of each vaginal electrode...

Development of a quasi-dry electrode for EEG recording

Mota, A. R.; Duarte, L.; Rodrigues, D.; Martins, A. C.; Machado, A. V.; Vaz, F.; Fiedler, P.; Haueisen, J.; Nóbrega, J. M.; Fonseca, C.
Fonte: Elsevier Publicador: Elsevier
Tipo: Artigo de Revista Científica
Português
Relevância na Pesquisa
36.84%
The present work reports on the development of a novel polymer-based electrode prototype for electroencephalography (EEG). The new electrode concept lies between the classic “wet” and “dry” electrodes, allowing addressing most of their drawbacks, while keeping the advantages of both. A localized skin hydration effect at the electrode/scalp contact point is achieved by the release of a small amount of a moisturizing agent (30 μl) from a reservoir inside the electrode, triggered by the electrode/scalp adduction. The electrode's functionality relies on the polymer mechanical properties and on the design of an electrode reservoir that deforms upon the application of a specified adduction force. Numerical modeling tools were used for the definition and analysis of the electrode geometry and the material mechanical properties. The new electrode prototype proved to be able to monitor EEG signals similar to those of the commercial silver/silver chloride electrodes by using a fraction of the hydrating solution necessary for the commercial electrodes, thus avoiding to damage or dirtying the patient's hair. Furthermore, due to the small amount of moisturizing agent employed, the risk of conductive bridges between adjacent electrodes due to gel running is considerably reduced.

Characterization approach to modified glassy carbon electrode-nanofilm system within multidimensional scaling

Machado, J. A. Tenreiro; Baleanu, Dumitru; Dinç, Erdal; Solak, Ali Osman; Eksi, Haslet; Güzel, Remziye
Fonte: American Scientific Publishers Publicador: American Scientific Publishers
Tipo: Artigo de Revista Científica
Publicado em //2011 Português
Relevância na Pesquisa
36.8%
The aim of this work is to characterize the nanofilm consisting of the benzoic acid-modified glassy carbon (GC) electrode system through multidimensional scaling space analysis. The surface modification is based on the electrochemical reaction between the GC electrode and benzoic acid-diazonium salt (BA-DAS). As a result, the nonofilms regarding the benzoic acid-glassy carbon (BA-GC) electrode surface was obtained. For the analysis of the naonfilm of BC-GC electrode system, the IR spectra of the modified BA-GC electrode surface, GC surface and BA-DAS were recorded in the spectral range of 599.84 – 3996.34 [cm–1]. The IR data vectors of the above three forms were processed by the using the multidimensional scaling space approach to demonstrate the existence of a nanofilm on the modified BA-GC electrode system. Two- and three-dimensional MDS profiles obtained by application of multidimensional scaling approach to the data sets {CG1,...,CG10}, {BA-GC1,...,BA-GC10} and {FILM1,...,FILM10} allow a good recognition of the nanofilm on the modified glassy carbon (GC) electrode system.

Degradação eletroquímica/química dos corantes têxteis Reativo Azul 19 e Reativo Preto 5 utilizando eletrodos de diamante dopado com boro e H2O2 eletrogerado em eletrodo de carbono vítreo reticulado; Electrochemical/chemical degradation of textile dyes Reactive Blue 19 and Reactive Black 5 using boron doped diamond electrodes and H2O2 electrogenerated in reticulated vitreous carbon electrode

Vasconcelos, Vanessa Moura
Fonte: Biblioteca Digitais de Teses e Dissertações da USP Publicador: Biblioteca Digitais de Teses e Dissertações da USP
Tipo: Tese de Doutorado Formato: application/pdf
Publicado em 11/09/2015 Português
Relevância na Pesquisa
36.77%
A problemática envolvendo os efluentes têxteis decorre principalmente da elevada coloração que apresentam, devido à presença de corantes que além de serem quimicamente estáveis, podem ser tóxicos e/ou carcinogênicos. Logo, quando são descartados in natura no meio ambiente causam problemas estéticos e, sobretudo, ambientais mesmo em baixas concentrações, além da possibilidade de serem nocivos à saúde humana e dos animais. Neste contexto, o objetivo deste trabalho foi estudar a degradação eletroquímica de dois corantes têxteis, Reativo Azul 19 (RA-19) e o Reativo Preto 5 (RP-5) via Oxidação Anódica (OA), utilizando ânodos de Diamante Dopado com Boro (DDB) suportados em titânio ou em nióbio, via processo Eletro-Fenton (EF) e pela combinação dos processos com H2O2 eletrogerado e OA (CP), usando um eletrodo de Carbono Vítreo Reticulado (CVR) como cátodo. As degradações foram realizadas em célula eletroquímica de um compartimento e em reator de fluxo do tipo filtro-prensa com dois compartimentos. A eficiência das degradações foi monitorada pelas técnicas de espectrofotometria no UV-VIS, Cromatografia Líquida de Alta Eficiência (CLAE) e análise do teor de Carbono Orgânico Total (COT). As variáveis estudadas foram densidade de corrente (10-100 mA cm-2 em célula e 4-41 mA cm-2 em reator)...

Efecto sobre la reacción de oxígeno de la forma y la microestructura del contacto electrodo-electrolito de electrodos a difusión interna en Celdas de Combustible de Óxido Sólido (SOFC); Internal diffusion electrode-electrolyte contact shape and microstructure effect on Solid Oxide Fuel Cells (SOFC) oxygen reaction

Otalora, Fermín; Kleitz, M.; Jiménez Espinosa, R.
Fonte: Sociedad Española de Cerámica y Vidrio Publicador: Sociedad Española de Cerámica y Vidrio
Tipo: Artículo Formato: 267039 bytes; application/pdf
Português
Relevância na Pesquisa
36.8%
[ES] En este trabajo, se estudia la influencia de la forma del electrodo elemental y la microestructura del contacto electrodo-electrolito, del electrodo de gas a difusión interna en celdas de combustible de óxido sólido (SOFC). Se determina la influencia de la microestructura del contacto electrodo electrolito sobre la resistencia efectiva del electrolito, la influencia de la forma del contacto de un grano elemental de un electrodo poroso suponiendo que sea aproximadamente una semiesfera sobre la reacción del electrodo y finalmente la influencia de la microestructura del contacto electrodo - electrolito en la respuesta a un control difusivo puro del electrodo. De los resultados obtenidos se pueden extraer conclusiones sobre la influencia de la microestructura del contacto y forma del electrodo en la reacción de oxígeno en este tipo de electrodos de gas.; [EN] In this work we have studied the elemental electrode shape and electrode - electrolyte contact microstructure influence of Internal diffusion (ID) gas electrode in solid oxide fuel cells (SOFC). First the influence over the electrolyte effective resistance is studied. Then the influence of the shape of the elemental contact grain of ID electrode is also studied. Finally the influence of the electrode - electrolyte contact microstructure in the electrode response for a pure diffuse control is modelled. From the obtained results...

Cell constant studies of bipolar and tetrapolar electrode systems for impedance measurement

Ma, Hanbin; Su, Yang; Nathan, Arokia
Fonte: Elsevier Publicador: Elsevier
Tipo: Article; accepted version
Português
Relevância na Pesquisa
36.8%
This is the author accepted manuscript. The final version is available from Elsevier via http://dx.doi.org/10.1016/j.snb.2015.07.089; In comparison to the bipolar or two-electrode system, the tetrapolar or four-electrode arrangement is a well-known technique to reduce electrode polarisation just as effectively. However, recent studies have showed that phenomena such as negative sensitivity and multiple current paths can compromise the advantages of the tetrapolar electrode arrangement, thereby potentially limiting its applications. This paper reveals a novel method to evaluate the performance of the different electrode systems in which the concept of cell constant is extended to an impedance measurement system. We employ it as a standardised parameter to quantitatively analyse planar electrode systems in bipolar and tetrapolar measurement modes. Indeed, the cell constant is a key parameter in conductivity sensors to evaluate electrodes designs since it is independent of any readout electronics. A comparison of measurement modes using finite element methods (FEM) simulations and measurements for sodium chloride solutions is presented. While the cell constant of the bipolar electrode system is one order of magnitude greater than that of the tetrapolar arrangement...

Psychophysics-Based Electrode Selection for Cochlear Implant Listeners

Duran, Sara Ingrid
Fonte: Universidade Duke Publicador: Universidade Duke
Tipo: Dissertação
Publicado em //2014 Português
Relevância na Pesquisa
36.86%

Cochlear implant listeners are presented with a time and frequency-quantized version of speech signals. In the frequency domain, resolution is limited by the number of electrodes in each listener's array. Current cochlear implant speech processing strategies implicitly assume that the information presented to each one of these electrodes is perceived as unique and independent. However, previous research suggests that stimuli presented on different electrodes can be indiscriminable (e.g. Zwolan et al., 1997; Throckmorton and Collins, 1999; Henry et al., 2000) . Additional studies suggest that stimuli presented on one electrode can influence the perception of stimuli on neighboring electrodes (e.g. Shannon, 1990; Chatterjee and Shannon, 1998; Boëx et al., 2003). Removing this redundant or occluded information could cause more distinct or perceivable information to be presented to the listener and possibly result in improved speech recognition.

Previous studies have used psychophysical data to identify the electrodes with the highest potential to confound speech recognition (Zwolan et al., 1997, Boëx et al., 2003, and Garadat et al., 2012). In order to minimize electrode interactions and maximize the amount of perceivable information...

Preparation and Characterization of a PVC/TTF-TCNQ Composite Electrode: Applications in a Flow Injection System

Cano,Manuel; Palenzuela,Beatriz; Rodríguez-Amaro,Rafael
Fonte: Sociedade Portuguesa de Electroquímica Publicador: Sociedade Portuguesa de Electroquímica
Tipo: Artigo de Revista Científica Formato: text/html
Publicado em 01/01/2007 Português
Relevância na Pesquisa
36.77%
It was prepared a new polyvinyl chloride (PVC)/tetrathiafulvalene-tetracyanoquinodimethane (TTF-TCNQ) composite electrode which showed good physical and electrochemical characteristics. Different PVC/TTF-TCNQ-graphite proportions were tested and the relation 1/10 (p/p) PVC/TTF-TCNQ provided the best results in terms of sensitivity, coefficients of variation and mechanical resistance. This electrode has interesting applications as a working electrode. So, employment is remarkable in a flow injection system and had been satisfactory checked to detect ascorbic acid. Also, the electrode exhibits selective voltammetric behaviour in aqueous solution that affords its use as an ion detector. The proposed electrode showed good kinetics property with a low background current and a relatively reproducible signal. Moreover, the electrode can be prepared in a simple way and its surface easily recovered.